包米勒高性能伺服驅(qū)動(dòng)器維修:2013Timeout quick discharge超時(shí)快速放電。The active mains rectifier unit calculates the discharging time from the maximum discharging resistor (see Instruction Manual) and the maximum DC link capacity according to the relation:電整流器單元根據(jù)以下關(guān)系式計(jì)算最大放電電阻器的放電時(shí)間(請(qǐng)參閱說明書)和最大直流鏈路容量:

 

If the discharging is triggered, the DC link is discharged always for at least 10 s via the discharging resistor. 如果觸發(fā)放電,則直流鏈路總是通過放電電阻器放電至少10 s

 

南通鮑米勒伺服驅(qū)動(dòng)器維修服務(wù):

If the DC link voltage is greater than 20 V after 10 s discharging time, then it is checked whether the calculated discharging time is greater than the so far elapsed discharging time of 10 s. 如果DC鏈路電壓在10s放電時(shí)間后大于20V,則檢查計(jì)算出的放電時(shí)間是否大于迄今為止經(jīng)過的10s的放電時(shí)間。

If this is not the case, the error is triggered at once.

如果不是這種情況,則會(huì)立即觸發(fā)錯(cuò)誤。

 

If the calculated discharging time is greater than 10 s and if the DC link voltage is greater than 20 V after the discharging time, then the error is triggered also in this case.如果計(jì)算的放電時(shí)間大于10s,并且如果DC鏈路電壓在放電時(shí)間之后大于20V,則在這種情況下也觸發(fā)誤差。

 

Possible causes: The chopper resistor is not connected or was selected too great. Possibly the DC link capacity is greater than specified (see Operating Instructions BM5000 (5.09021)).可能的原因:斬波電阻器未連接或選擇得太大。直流鏈路容量可能大于規(guī)定值(請(qǐng)參閱操作說明BM50005.09021))。



轉(zhuǎn)載請(qǐng)注明出處:上海仰光電子科技專業(yè)伺服驅(qū)動(dòng)器維修,伺服電機(jī)維修
本文鏈接:http://www.55669o.com/fuwu/Services_Show21358.htm
伺服驅(qū)動(dòng)器維修 伺服電機(jī)維修  觸摸屏維修   變頻器維修


聯(lián)系方式:

電話:021-50157782
手機(jī):13817011982 微信同號(hào)
郵箱:shygdzi@163.com
聯(lián)系人:張工
網(wǎng)址:http://www.55669o.com
【 我們確保修好測試好給客戶!!!!】

上一篇:力士樂Rexrotha伺服電機(jī)常見輸出轉(zhuǎn)矩不穩(wěn)定維修
下一篇:東曹凝膠滲透色譜儀HLC-8321GPC常見故障維修方法

最新相關(guān)內(nèi)容推薦: